1,876 research outputs found

    Measurement Invariance of the Internet Addiction Test Among Hong Kong, Japanese, and Malaysian Adolescents

    Get PDF
    There has been increased research examining the psychometric properties on the Internet Addiction Test across different ages and populations. This population-based study examined the psychometric properties using Confirmatory Factory Analysis and measurement invariance using Item Response Theory (IRT) of the IAT in adolescents from three Asian countries. In the Asian Adolescent Risk Behavior Survey (AARBS), 2,535 secondary school students (55.91% girls) in Grade 7 to Grade 13 (Mean age = 15.61 years; SD=1.56) from Hong Kong (n=844), Japan (n=744), and Malaysia (n=947) completed a survey on their Internet use that incorporated the IAT scale. A nested hierarchy of hypotheses concerning IAT cross-country invariance was tested using multi-group confirmatory factor analysis. Replicating past finding in Hong Kong adolescents, the construct of IAT is best represented by a second-order three-factor structure in Malaysian and Japanese adolescents. Configural, metric, scalar, and partial strict factorial invariance was established across the three samples. No cross-country differences on Internet addiction were detected at latent mean level. This study provided empirical support to the IAT as a reliable and factorially stable instrument, and valid to be used across Asian adolescent populations

    The performance of thin NaI(Tl) scintillator plate for dark matter search

    Full text link
    A thin (0.05cm) and wide area (5cmX5cm) NaI(Tl) scintillator was developed. The performance of the thin NaI(Tl) plate, energy resolution, single photoelectron energy and position sensitivity were tested. An excellent energy resolution of 20% (FWHM) at 60keV was obtained. The single photoelectron energy was calculated to be approximately 0.42 0.02keV. Position information in the 5cmx5cm area of the detector was also obtained by analyzing the ratio of the number of photons collected at opposite ends of the detector. The position resolution was obtained to be 1cm (FWHM) in the 5cmx5cm area.Comment: 10 pages. Accepted to Journal of Physical Society of Japa

    Performance measurements of mixed data acquisition and LAN traffic on a credit-based flow-controlled ATM network

    Get PDF

    Performance of a Low Noise Front-end ASIC for Si/CdTe Detectors in Compton Gamma-ray Telescope

    Full text link
    Compton telescopes based on semiconductor technologies are being developed to explore the gamma-ray universe in an energy band 0.1--20 MeV, which is not well covered by the present or near-future gamma-ray telescopes. The key feature of such Compton telescopes is the high energy resolution that is crucial for high angular resolution and high background rejection capability. The energy resolution around 1 keV is required to approach physical limit of the angular resolution due to Doppler broadening. We have developed a low noise front-end ASIC (Application-Specific Integrated Circuit), VA32TA, to realize this goal for the readout of Double-sided Silicon Strip Detector (DSSD) and Cadmium Telluride (CdTe) pixel detector which are essential elements of the semiconductor Compton telescope. We report on the design and test results of the VA32TA. We have reached an energy resolution of 1.3 keV (FWHM) for 60 keV and 122 keV at 0 degree C with a DSSD and 1.7 keV (FWHM) with a CdTe detector.Comment: 6 pages, 7 figures, IEEE style file, to appear in IEEE Trans. Nucl. Sc

    Bremsstrahlung of 350--450 MeV protons as a tool to study NNNN interaction off-shell

    Get PDF
    The ppppγpp\to pp\gamma bremsstrahlung cross section is calculated within the method of coordinate space representation. It is shown that in the beam energy range of 350--450~MeV a deep attractive NN-potential with forbidden states (Moscow potential) and realistic meson exchange potentials (MEP) give rise to the cross sections that differ essentially in shape: the cross sections nearly coincide in the minima but differ by a factor of 5 approximately in the maxima. Therefore, the ppppγpp\to pp\gamma reaction at energies \sim350--450~Mev can be used to study NNNN interaction off-shell and to discriminate experimentally between MEP and Moscow potential.Comment: 5 pages, latex, 4 PS figures. Talk presented by Andrey Shirokov at the International Conference on Quark Lepton Nuclear Physics ``QULEN97'', May 20-23, 1997, Osaka, Japan; to be published in Nucl. Phys.

    On-site underground background measurements for the KASKA reactor-neutrino experiment

    Get PDF
    On-site underground background measurements were performed for the planned reactor-neutrino oscillation experiment KASKA at Kashiwazaki-Kariwa nuclear power station in Niigata, Japan. A small-diameter boring hole was excavated down to 70m underground level, and a detector unit for γ\gamma-ray and cosmic-muon measurements was placed at various depths to take data. The data were analyzed to obtain abundance of natural radioactive elements in the surrounding soil and rates of cosmic muons that penetrate the overburden. The results will be reflected in the design of the KASKA experiment.Comment: 9 pages, 7 figures, final version for publication. Table 1 and Fig.5 have change

    Pulse Shape Discrimination of CsI(Tl) with a Photomultiplier Tube and MPPCs

    Full text link
    In this study, we evaluate and compare the pulse shape discrimination (PSD) performance of multipixel photon counters (MPPCs, also known as silicon photomultiphers - SiPMs) with that of a typical photomultiplier tube (PMT) when testing using CsI(Tl) scintillators. We use the charge comparison method, whereby we discriminate different types of particles by the ratio of charges integrated within two time-gates (the delayed part and the entire digitized waveform). For a satisfactory PSD performance, a setup should generate many photoelectrons (p.e.) and collect their charges efficiently. The PMT setup generates more p.e. than the MPPC setup does. With the same digitizer and the same long time-gate (the entire digitized waveform), the PMT setup is also better in charge collection. Therefore, the PMT setup demonstrates better PSD performance. We subsequently test the MPPC setup using a new data acquisition (DAQ) system. Using this new DAQ, the long time-gate is extended by nearly four times the length when using the previous digitizer. With this longer time-gate, we collect more p.e. at the tail part of the pulse and almost all the charges of the total collected p.e. Thus, the PSD performance of the MPPC setup is improved significantly. This study also provides an estimation of the short time-gate (the delayed part of the digitized waveform) that can give a satisfactory PSD performance without an extensive analysis to optimize this gate
    corecore